Troubleshooting the pneumatic solenoid valve
As to troubleshooting the pneumatic solenoid valve, we should first clarify types of the pneumatic solenoid valve, including two-position two-port (2/2 way), two-position three-port (3/2 way), two-position five-port (5/2 way), etc. Generally, the solenoid valve has two state, namely, power-on is one state and power-off is another state. The on-off state between different ports is different under every state.
It is suggested that the air at a low pressure should be blown in to see which ports are barrier-free upon power-off and power-on. This can help tell whether the pneumatic solenoid valve is good or bad.
Besides, when there is no air supply, you can blow in smog to see how the smog flows. You can ask smokers for help, and they must be very willing to do you the favor. If there are any problems, the pneumatic solenoid valve should be disassembled for repair. Usually, the problem is caused by blocking of some materials or abrasion-induced air leakage. If the sealing elements are damaged, it is easy to repair. If the repair fails, they should be changed for new ones rather than used continuously.
Daily maintenance of the pneumatic solenoid valve
The pneumatic solenoid valve demonstrates a favorable performance, whose fault rate is lower than that of other solenoid valves. This can also explain the former's wide applications. However, the pneumatic solenoid valve, if used for a long time under the influence of physical factors, such as production materials, various faults might be easily caused. Below are key points for daily maintenance of pneumatic solenoid valve.
1. Disassemble and remove the internal impurities, and check whether various parts suffer serious abrasion. Consider whether to change or repair the damaged parts according to practical situations.
2. When the pneumatic solenoid valve is disassembled, disconnect the power, and turn off other electric equipment, and pay attention to the installation sequence of various parts in the solenoid valve during the process of disassembly.
3. Faults of the pneumatic solenoid valve can easily happen to damageable parts, including coils and sealing elements. Burning of coils are caused by overload working. The sealing elements are damageable elements, and cannot avoid natural abrasion under long-term working status.
4. When the pneumatic solenoid valve is working and the vibration occurs frequently, components of the pneumatic solenoid valve might be easily damaged. Therefore, maintenance of the solenoid valve should also ensure stability of the working environment and periodically fix the components, such as screws and nuts, of the pneumatic solenoid valve.
5.When the working environment of the pneumatic electronic valve is in the open air, it might result in rustiness of the pneumatic solenoid valve and parts, thus making it impossible for the solenoid valve to operate. Therefore, maintenance is necessary which can ensure steady operation of the solenoid valve.
6.If the pneumatic solenoid valve is operating in an important place and the conditions are allowable, the specialized maintenance personnel should be employed to ensure steadiness and low fault rate of the solenoid valve. Only in this way can its working efficiency be improved, the maintenance cost be further reduced, and the service life be longer.
As to troubleshooting the pneumatic solenoid valve, we should first clarify types of the pneumatic solenoid valve, including two-position two-port (2/2 way), two-position three-port (3/2 way), two-position five-port (5/2 way), etc. Generally, the solenoid valve has two state, namely, power-on is one state and power-off is another state. The on-off state between different ports is different under every state.
It is suggested that the air at a low pressure should be blown in to see which ports are barrier-free upon power-off and power-on. This can help tell whether the pneumatic solenoid valve is good or bad.
Besides, when there is no air supply, you can blow in smog to see how the smog flows. You can ask smokers for help, and they must be very willing to do you the favor. If there are any problems, the pneumatic solenoid valve should be disassembled for repair. Usually, the problem is caused by blocking of some materials or abrasion-induced air leakage. If the sealing elements are damaged, it is easy to repair. If the repair fails, they should be changed for new ones rather than used continuously.
Daily maintenance of the pneumatic solenoid valve
The pneumatic solenoid valve demonstrates a favorable performance, whose fault rate is lower than that of other solenoid valves. This can also explain the former's wide applications. However, the pneumatic solenoid valve, if used for a long time under the influence of physical factors, such as production materials, various faults might be easily caused. Below are key points for daily maintenance of pneumatic solenoid valve.
1. Disassemble and remove the internal impurities, and check whether various parts suffer serious abrasion. Consider whether to change or repair the damaged parts according to practical situations.
3. Faults of the pneumatic solenoid valve can easily happen to damageable parts, including coils and sealing elements. Burning of coils are caused by overload working. The sealing elements are damageable elements, and cannot avoid natural abrasion under long-term working status.
4. When the pneumatic solenoid valve is working and the vibration occurs frequently, components of the pneumatic solenoid valve might be easily damaged. Therefore, maintenance of the solenoid valve should also ensure stability of the working environment and periodically fix the components, such as screws and nuts, of the pneumatic solenoid valve.
5.When the working environment of the pneumatic electronic valve is in the open air, it might result in rustiness of the pneumatic solenoid valve and parts, thus making it impossible for the solenoid valve to operate. Therefore, maintenance is necessary which can ensure steady operation of the solenoid valve.
6.If the pneumatic solenoid valve is operating in an important place and the conditions are allowable, the specialized maintenance personnel should be employed to ensure steadiness and low fault rate of the solenoid valve. Only in this way can its working efficiency be improved, the maintenance cost be further reduced, and the service life be longer.